Show simple item record

dc.contributor.authorWright, John L.
dc.contributor.authorSullivan, Harry F.
dc.date.accessioned2017-03-22 17:46:11 (GMT)
dc.date.available2017-03-22 17:46:11 (GMT)
dc.date.issued1995-08
dc.identifier.otherCH-95-8-3
dc.identifier.urihttp://hdl.handle.net/10012/11576
dc.description© 1995. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol. 101, Part 1. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission.en
dc.description.abstractA simple two-dimensional (2-D) numerical control volume formulation is presented that can be used to model heat transfer through a vertical insulated glazing unit. This model accounts for natural convection of the fill gas (including the effect of secondary cells), conduction within the solid materials, and radiant exchange between the various surfaces facing the fill-gas cavity. This model closely reproduces average and local heat transfer rates measured using a guarded heater plate apparatus. Simulations clearly show that fill-gas motion causes the minimum indoor surface temperature (during cold weather) to be located at the bottom edge of the indoor glazing. Calculated results were also used to gain insights into heat transfer patterns in glazing systems with various combinations of low-emissivity coatings, fill gases, and edge-seal designs.en
dc.description.sponsorshipCANMET (Natural Resources Canada) || Natural Sciences and Engineering Research Council of Canadaen
dc.language.isoenen
dc.publisherAmerican Society of Heating, Refrigerating and Air-Conditioning Engineersen
dc.subjectEnergy conservationen
dc.subjectEnergy consumptionen
dc.subjectWindowsen
dc.subjectMathematical modelsen
dc.subjectHeat transferen
dc.subjectCommercial buildingsen
dc.subjectResidential buildingsen
dc.subjectEnergy utilizationen
dc.titleA two-dimensional numerical model for glazing system thermal analysisen
dc.typeArticleen
dcterms.bibliographicCitationWright, J.L., Sullivan H.F., "A Two-Dimensional Numerical Model for Glazing System Thermal Analysis," ASHRAE Transactions, Vol 101, Pt. 1 (1995) pp. 819-831.en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages